Building Standards - Warehouse Space
LIGHTING:
Will be unshielded, fluorescent ribbon light fixtures with two 8' tubes, in suspended fixtures.
WALLS:
Walls separating tenant's demised premises shall be constructed using 6" steel studs with 5/8"
gypsum board on each side, finished to the underside of the deck above, insulated, taped, spackled and painted.
DOORS / HARDWARE:
Loading dock overhead doors to be 8' x 8' vinyl insulated exterior grade
Loading dock access doors to be 1 3/4' x 3'-0" x 7'-0" insulated hollow
metal with closer and Schlage lock set hardware (ADA Approved).
FLOORING:
6" reinforced concrete floor slab
WINDOW TREATMENTS:
Landlord will furnish and install 1" metal horizontal window blinds - Hunter Douglas or
equal on all exterior windows.
ELECTRICAL SERVICE:
To a distribution panel which shall have the capacity of 7.0 watts per square
foot; to provide 5.5 watts per rentable square foot @ 120 volts for power distribution,
and 1.5 watts per rentable square foot for lighting.
HVAC:
Heating units to be suspended area heaters as required.
FIRE PROTECTION:
Wet fire sprinkler system throughout in accordance with the building
standard plan. In any event, such system shall be sufficient to comply with
all applicable laws, regulations and ordinances. Electronically monitored fire alarm.
|
 |